Current transformers with several core materials for various demands

R1405XB1, R1405XB7T, R1405X11, R1405X10

 

Download scale drawing

Versions Inductance Current [A] Remarks

case - vertical

case - horizontal

naked - vertical

naked - horizontal

300/1

425/1

5

  • AC current detection (at 50/60Hz)
  • AC current measurement possible at higher frequencies
  • intermediate parameters available
  • cup versions have reduced ampacity
 

R1405ZB1, R1405Z11, R1405Z10

 

Download scale drawing

Versions

Turns ratio

Current [A]

Remarks

case - vertical

naked - vertical

naked - horizontal

300/1

12

  • AC current measurement at best linearity
  • Intermediate parameters available
  • cup versions have reduced ampacity
 

R2607BB-B3215, R2607BB-B3218, R2607BB-B4, R2607BB11, R2607BB10

 

Download scale drawing

Versions

Turns ratio

Current [A]

Remarks

case - vertical

case - horizontal

naked - vertical

naked - horizontal

640/1

750/1

60

  • AC current measurement at highest saturation degree
  • intermediate parameters available
  • cup versions have reduced ampacity
 

R2610XB3215, R2610XB3218, R2610XB4, R2610X11, R2610X10

 

Download scale drawing

Versions

Turns ratio

Current [A]

Remarks

case - vertical

case - horizontal

naked - vertical

naked - horizontal

640/1

750/1

25

  • AC current detection (at 50/60Hz)
  • AC current measurement possible at higher frequencies
  • intermediate parameters available
  • cup versions have reduced ampacity
 

R2610ZB3215, R2610ZB3218, R2610ZB4, R2610Z11, R2610Z10

 

Download scale drawing

Versions

Turns ratio

Current [A]

Remarks

case - vertical

case - horizontal

naked - vertical

naked - horizontal

640/1

750/1

60

  • AC current measurement at best linearity
  • intermediate parameters available
  • cup versions have reduced ampacity
 

R3615XB44.25, R3615X11, R3615X10

 

Download scale drawing

Versions

Turns ratio

Current [A]

Remarks

case - horizontal

naked - vertical

naked - horizontal

400/1

1000/1

60

  • AC current detection (at 50/60Hz)
  • AC current measurement possible at higher frequencies
  • intermediate parameters available
  • cup versions have reduced ampacity
 

R4015BB-B44.25, R4015BB11, R4015BB10

 

Download scale drawing

Versions

Turns ratio

Current [A]

Remarks

case - vertical

naked - vertical

naked - horizontal

750/1

1000/1

200

  • AC current measurement at highest saturation degree
  • intermediate parameters available
  • cup versions have reduced ampacity

 

Adress


NKL GmbH
Birkichstrasse 15

D-74549 Wolpertshausen

 

Tel: +49 (0) 7904 / 97 81-0

E-Mail: NKL GmbH

Products


Common mode chokes

Single chokes

EMI Filters

Storage chokes

PFC chokes

Current sensors

Signal transformers

Special designs

Services


EMC testing

EMC consulting

EMI suppression

Open area test site

Mains harmonics testing

Flicker testing